1 This test method is under the jurisdiction of ASTM Committee G01 on Last previous edition approved in as C–91(), which. ASTM C Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete. The ASTM standard C [3] provides general guidelines for the . ASTM C 91() “Standard Test Method for Half-Cell Potentials of.

Author: Kagadal Makinos
Country: Malawi
Language: English (Spanish)
Genre: Love
Published (Last): 9 November 2018
Pages: 115
PDF File Size: 1.83 Mb
ePub File Size: 19.72 Mb
ISBN: 849-4-56301-357-1
Downloads: 42231
Price: Free* [*Free Regsitration Required]
Uploader: Durr

Concrete cover in excess of 3 in. Once the alkaline environment is destroyed, the protective layer of oxide on the steel surface is destroyed and corrosion may start. Introduction Corrosion is the loss of material and occurs when metals are exposed to the environment. However, the passive layer does not provide a perfect and permanent barrier in aggressive environments containing initiators of corrosion primarily aggressive ions like sulphates and chlorides, humidity, carbon dioxide, and oxygen [4].

CANIN, Half Cell Potential Concrete Equipment | PCTE

Single files can be opened and processed separately. Sydney e This email address is being protected from spambots. This statistical presentation is the basis for an efficient interpretation of the half-cell potentials by the corrosion engineer. Data collection and processing of test results comply with major industry standards:.

The results showed that reinforced concrete containing sugar cane bagasse ash has the lowest corrosion rates in comparison to reinforced concrete without the additive. The basic configuration of the electrical circuit is shown in Fig. It is often necessary to use other data such as chloride contents, depth of carbonation, delamination survey findings, rate of corrosion results, and environmental exposure conditions, in addition to corrosion potential measurements, to formulate conclusions concerning corrosion activity of embedded steel and its probable effect on the service life of a structure.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The program generates a potential map, a relative frequency and a cumulative frequency diagram and provides a chipping graph. Firstly, accurate field corrosion potential measurements aid in detecting corrosion in rebars. Separately measured objects can be merged to a complete potential map.

  HIPERHIDROSIS PALMAR PDF

Corrosion of reinforced steel has two principal problems that affect the service life of concrete reinforced structures [2]. These factors, together with inadequate construction practices in difficult environmental conditions, lead to corrosion of the reinforcing steel. Lecture Slides Our Products: The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Six AA batteries, 1. Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. RS interface, USB with adapter.

XY-grid settings must be equal. Comments about specific points on the concrete structure can be placed directly in the potential map. Carbon dioxide can cause corrosion primarily by reducing the pH of the concrete. All specimens were placed in a 3. Reinforced concrete structures are exposed to.

Perth Head Office e This email address is being protected from spambots. Corrosion of steel in concrete is an electrochemical process. Additives, such as fly ash, microsilica, rice husk ash, and cane sugar bagasse ash, have a size breakdown that allows the reduction of concrete pore size and, consequently, may reduce the corrosion process.

All graphics can be exported as bmp-files into external software for the generation of reports. This is the result of the interaction between chemical and biological agents [1]. You need JavaScript enabled to view it.

For the latest corrosion mapping system from Proceq please take a look at the Profometer Corrosion. It enables the identification of concrete corrosion before it becomes visible and has caused damage. Link to Active This link will always route to the current Active version of the standard.

If required, objects can be rotated and mirrored. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

  FUNDAMENTOS DE PSICOLOGIA FISIOLOGICA NEIL CARLSON PDF

Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered asttm this test method may be required see 5. A potential field can be measured on the concrete surface by the use of an electrode, known as a half-cell, and a high-impedance voltmeter. The concrete cover provides an alkaline environment surrounding the steel, resulting in the formation of an oxide layer, called a passive film, which protects the steel from corrosion.

Historical Version s – view previous versions of standard.

has been cited by the following article:

Degradation of concrete structures by corrosion processes is a serious problem and has major economic implications [3]. Selectable grid with metric or imperial units.

Up to measurement values are displayed at a time in easy-to read grey-scale and a menu-driven approach facilitates simple operation using just nine keys.

Based on the user defined threshold potentials that represent certain conditions of the structure, up to four characteristic potential intervals can be chosen. This enable the inspector to immediately mark on the concrete surface the areas of concern and to later down load the data for printing in a report.

Readings are collected at a predetermined spacings automatically and stored. This early detection can be a key in preventing an unanticipated structural failure. Brisbane e This email address is being protected from spambots. Concrete is a porous material and the ingress of water, oxygen, and aggressive ions, such as chlorides, can cause the passive layer on asgm steel to break down.

In service conditions, the concrete covering the steel bars gives physical and chemical protection to the reinforcement.